Search results for " Electric storage"

showing 2 items of 2 documents

Impact of Demand Response Control Logic on Isolated Island's Distribution Networks

2019

The work presents the results of a study regarding the impact of some Demand Response control logics on an isolated distribution network. The proposed control is divided into precise steps in which the coordination between the general aggregator controller and the single local Energy Management Systems is developed and illustrated with details. The control is applied to the flexible loads and to the storage systems of photovoltaic plants installed at the end-users' houses and connected to the network. The study is carried out delivering a suitable network model of the island's system, with the implementation of load profiles for all the loads of the network for a total simulation time of 24…

Demand responseelectric storageComputer scienceEnergy managementPhotovoltaic systemControl (management)demand response; EES; electric storage; flexible loads; load aggregation; photovoltaic; PV; small islandsflexible loadsload aggregationControl engineeringPVcomputer.software_genresmall islandsEESNews aggregatorphotovoltaicSettore ING-IND/33 - Sistemi Elettrici Per L'EnergiaDemand responseflexible loadControl theoryControl logiccomputerNetwork model2019 IEEE 5th International forum on Research and Technology for Society and Industry (RTSI)
researchProduct

A Procedure for the Producibility Curve Identification of a Dish-Stirling Plant, Starting from Experimental Data

2019

This article presents a procedure for the producibility curve identification of a dish-Stirling plant, starting from experimental data. The producibility data was measured, recorded, analysed, filtered and monthly aggregated. Moreover, the incidence of the ambient temperature and of the mirrors cleaning on producibility data is highlighted and a procedure to normalize the measured data in temperature and cleaning level was developed. To provide a validation of the developed procedure the producibility curves at 25 °C have been obtained and compared with the one issued by the manufacturer. The two curves are in good agreement, presenting a maximum deviation of the 7 %.

Stirling engineSettore ING-IND/11 - Fisica Tecnica Ambientalebusiness.industry020209 energyMaximum deviationExperimental data02 engineering and technologySettore ING-IND/32 - Convertitori Macchine E Azionamenti ElettriciThermal energy storagelaw.inventionRenewable energyIdentification (information)020401 chemical engineeringlawHybrid systemSolar plant0202 electrical engineering electronic engineering information engineeringDish Stirling Electric storage Hybrid Systems Renewable Energy Solar plant Thermal StorageEnvironmental science0204 chemical engineeringProcess engineeringbusiness
researchProduct